Technical Parameter

PPK-M

Item No.

Thread Spec

Thread OD(AG)mm

Thread Length(GL)mm

Blanking Plug OD(D)mm

Holing(mm)

Color

Condition

RPK-M12-13

M12x1.5

12

13

16

Φ12.2-Φ12.4

BK/GY

RPK-M16-10

M16x1.5

16

10

19

Φ16.2-Φ16.4

BK/GY

RPK-M18-10

M18x1.5

18

10

22

Φ18.2-Φ18.4

BK/GY

RPK-M20-10

M20x1.5

20

10

24

Φ20.2-Φ20.4

BK/GY

RPK-M22-10

M22x1.5

22

10

27

Φ25.2-Φ25.4

BK/GY

D

RPK-M25-10

M25x1.5

25

10

29

Φ25.2-Φ25.4

BK/GY

D

RPK-M25-15

M25x1.5

25

15

30.5

Φ25.2-Φ25.4

BK/GY

RPK-M32-11

M32x1.5

32

11

38

Φ32.2-Φ32.4

BK/GY

RPK-M40-15

M40x1.5

40

15

52

Φ40.3-Φ40.5

BK/GY

RPK-M50-12

M50x1.5

50

12

56

Φ50.3-Φ40.5

BK/GY

D

RPK-M63-6.5

M63x1.5

63

6.5

70

Φ63.3-Φ63.5

BK/GY

RPK-M63-4

M63x1.5

63

14

70

Φ63.3-Φ63.5

BK/GY

D

RPK-PG

RPK-PG7-8

PG7

12.5

8

15

Φ12.7-Φ13

BK/GY

D

RPK-PG9-10

PG9

15.2

10

19

Φ15.4-Φ15.7

BK/GY

D

RPK-PG11-10

PG11

18.6

10

22

Φ18.8-Φ19.1

BK/GY

D

RPK-PG13.5-10

PG13.5

20.4

10

24

Φ20.6-Φ20.9

BK/GY

D

RPK-PG16-10

PG16

22.5

10

26

Φ22.7-Φ23

BK/GY

D

RPK-PG21-10

PG21

28.3

10

32.5

Φ28.5-Φ28.8

BK/GY

D

RPK-PG29-11

PG29

37

11

43

Φ37.2-Φ37.5

BK/GY

D

RPK-PG36-12

PG36

47

12

53

Φ47.2-Φ47.5

BK/GY

D

RPK-PG42-12

PG42

54

12

60

Φ54.2-Φ54.5

BK/GY

D

RPK-PG48-12

PG48

59.3

14

69

Φ59.5-Φ59.8

BK/GY

RPK-NPT

RPK-NPT1/2

NPT1/2

21.3

10

24

Φ21.5-Φ21.7

BK/GY

D

RPK-NPT3/4

NPT3/4

26.7

10

31

Φ26.9-Φ27.1

BK/GY

D

RPK-NPT1

NPT1

33.4

15

42

Φ33.6-Φ33.8

BK/GY

RPK-NPT1 1/4

NPT1 1/4

42.2

12

48

Φ42.4-Φ42.6

BK/GY

D

RPK-NPT2

NPT2

60.3

14

68

Φ60.6-Φ60.8

BK/GY

D

 

Cable connectors are defined as "mechanical cable entry equipment" for the cabling and wiring of electrical, instrumentation, control and automation systems, including lighting, power, data and telecommunications.

The cable gland's primary function is as a sealing and termination device to ensure protection of electrical equipment and enclosures, including the provision of:

Environmental protection - protects electrical or meter housing from dust and moisture through sealing of external cable sheathing.

Ground continuity - In the case of armored cables, the cable gland is of metal construction. In this case, the cable joints can be tested to ensure that they can withstand the appropriate peak short circuit fault current.

Holding force - on the cable to ensure adequate level of mechanical cable "pull out" resistance.

Additional seal - when a high degree of inlet protection is required, at the part where the cable enters the housing.

Additional environmental sealing - At the cable entry point, the entry protection class of the enclosure is maintained by selecting applicable accessories dedicated to performing the function.

Cable joints may be constructed from metallic or non-metallic materials (or a combination of both), which may also be resistant to corrosion, depending on the selection criteria or by passing corrosion resistance tests.

Especially when used in explosive environments, it is essential that, for the type of cable chosen, the cable joints are approved and that the level of protection of the connected equipment is maintained.

 


  • RPK-MP/G/NPT Nylon Blanking Plug Related Video: